Balem
valves
PVL
is the UK distributor for Balem of South Korea,
a company that has been specializing in the manufacture of
hydraulic level control valves and automatic control valves
for the past 20 years. All Balem valves are laboratory tested
with 200 horse power pumps with a water reservoir of over
300 tons capacity.
We
can supply float valves with bodies in cast iron, bronze,
brass or stainless steel, with floats of stainless steel or
plastic and suitable for pressures of up to 20 bar. Flanged
valves are available with flanges of up to 12" (300mm)
If
you were looking for solenoid valves, then you need our Solenoid
Valves Page
|
|
|
BALEM
411
|
LIQUID
LEVEL BALL VALVE - BRASS OR S/STEEL
|
|

|
-
Sizes
from 1/2" to 2" BSP
-
Brass
or stainless steel body with s/steel
float (304)
-
Up
to 10 bar (brass) and 20 bar (stainless
steel)
-
Provides
automatic level control for tanks
-
Temperatures
up to 110degC
-
PTFE
bearing/seal
-
|
|
|
|
 |
|
BALEM
421
|
LIQUID
LEVEL CONTROL VALVE - BRONZE
|
|

|
-
Sizes
from 1" to 3" BSP
-
Cast
bronze body with stainless steel float
(304)
-
Up
to 15 bar working pressure and 80 degC
-
Provides
automatic level control for tanks
-
High
flow rates available
-
Adjustable
flow control feature
-
|
|
|
|
 |
|
BALEM
431
|
LIQUID
LEVEL CONTROL VALVE - CAST IRON
|
|

|
-
Sizes
from 2½" to 10" flanges
-
Cast
iron body with bronze internals
-
Up
to 15 bar working pressure and 80 degC
-
Provides
automatic level control for tanks
-
High
flow rates available
-
Adjustable
flow control feature
-
|
|
|
|
 |
|
BALEM
441
|
SOLENOID/FLOAT
CONTROL VALVE
|
|

|
-
Stainless
steel valve suitable for pipe sizes
up to 12"
-
The
level can be controlled by an electrical
signal with a manual safety shut off
- or operated manually with an electrical
safety override
-
Vertical
(illustrated) or horizontal models
-
Up
to 15 bar working pressure and 80 degC
-
|
|
|
|
|
BALEM
511
|
LEVELS CONTROL VALVE FOR 2 X LEVELS
|
|

|
-
High and low water level control(1,200mm
Max.)
-
Opening
and Closing by rotating ball in the
valve's body
-
Mechanical
On/Off type
-
Anti-corrosion and heat-resistant materials
-
Easy
to install and maintain
-
|
|
|
|
|
BALEM
521
|
LIQUID
LEVEL BALL VALVE - PLASTIC
|
|

|
-
Sizes
from 1/2" to 1½" BSP
-
Plastic
body, arm & float
-
0.2
to 10 bar working pressure
-
Provides
automatic level control for tanks
-
Temperatures
up to 60degC
-
Operates
on differential principle which results
in high flow rates
|
|
|
|
 |
|
BALEM
531
|
LIQUID
LEVEL CONTROL VALVE - S/STEEL
|
|

|
-
Sizes
from 1" to 3" BSP
-
Cast
stainless steel body with stainless
steel float (304)
-
Up
to 15 bar working pressure and 80 degC
-
Provides
automatic level control for tanks
-
High
flow rates available
-
Adjustable
flow control feature
-
|
|
|
|
 |
|
BALEM
131-010
|
FLOAT
CONTROL VALVE - MODULATING (CONSTANT LEVEL)
|
|

|
Model
131-010 consists of Basic Valve (BALEM 130)
and Buoyancy pilot valve. It controls outflow
in a water supply tank and/or in a reservoir
to maintain constant water level. A double
chamber structure minimizes the effect of
the valve action due to whirlpool in the
valve and is easy to install and maintain
- Completely
automatic operation without Electric Power
Source
- Easy
Installation and Maintenanc
|
|
|
|
|
BALEM
131-020
|
FLOAT
CONTROL VALVE - ON/OFF (2 X CONSTANT LEVELS)
|
|

|
Model 131-020 consists of Basic Valve(BALEM
130) and Two-Level Pilot Valve(BALEM 511).
It can control water levels from 300mm up
to 1200mm in a storage tank, and mechanically
on-off operation controls opening and closing
when water level reaches the set heights.
|
|
|
|
|
BALEM
132-010
|
PRESSURE
REDUCING VALVE
|
|

|
Model
132-010 consists of Basic valve(BALEM 130)
and Pressure Reducing Pilot valve(Model
562). It automatically reduces and maintains
constant pre-set low pressure according
to flow rate change and/or inlet pressure
change.
|
|
|
|
|
BALEM
132-020
|
PRESSURE
REDUCING & CHECK VALVE
|
|

|
Model
132-020 consists of Basic Valve(BALEM 130)
and Pressure Reducing Pilot valve(Model
562). It maintains constant pre-set low
pressure according to inlet pressure change
and/or downstream flow rate change, and
once downstream pressure is higher than
inlet pressure closes the opening and closing
of the basic valve to prevent backflow caused
by back pressure.
|
|
|
|
|
BALEM
132-030
|
PRESSURE
REDUCING & PRESSURE SUSTAINING VALVE
|
|

|
Model
132-030 consists of Basic Valve(BALEM 130)
and Pressure Reducing Pilot valve(Model 562)
and Relief Pilot valve(Model 573). It maintains
constant downstream pressure and it sustains
the upstream pressure to a pre-determined
minimum.
- Accurate
Response to Slight Pressure Changes
- Completely
automatic operation without Electric Power
Source
- Drip
Tight, Safe Hydraulic Control
WATCH
A VIDEO DEMONSTRATION
|
|
|
|
|
BALEM
132-040
|
PRESSURE
REDUCING/SUSTAINING & CHECK VALVE
|
|

|
Model
132-040 combined Pressure Reducing(Model
562) and Pressure Sustaining(Model 573)
and Check valve maintains inlet pressure
change and/or downstream pressure flow rate
to a predetermined minimum pressure. Also
prevents functions if inlet pressure drops
lower than preset pressure and once downstream
pressure is higher than inlet pressure,
the valve closes to prevent backflow caused
by back pressure.
|
|
|
|
|
BALEM
132-050
|
PRESSURE
REDUCING & SOLENOID SHUT-OFF VALVE
|
|

|
Model
132-050 consists of basic valve(BALEM 130)
and pressure Reducing(Model 562) and Solenoid
on-off pilot valve. This valve automatically
reduces higher inlet pressure to a steady
lower downstream pressure according to flow
rate change and/or inlet pressure change.
It is a pressure reducing and solenoid control
valve that can control the opening and closing
of the basic valve remotely by controling
solenoid pilot valve electrically.
|
|
|
|
|
BALEM
132-060
|
PRESSURE
CONTROLLER & 2-STAGE PRESSURE CONTROL
VALVE
|
|

|
Model
132-060 consists of Basic Valve(BALEM 130),
Two Pressure Reducing Pilot Valve(Model
562) and Valve Control Device(Model VCD-01).
It has one pilot set at a higher pressure
setting for times of high water demand;
a second pilot set at a lower pressure setting
for low demand. This valve is suitable for
many pressure control applications for high
two-pressure control of a distribution zone.
Controller can be used without electric
power because of a built-in battery and
also program is easily set by remote control.
|
|
|
|
|
BALEM
132-070
|
2-STAGE
PRESSURE REDUCING & SOLENOID CONTROL
VALVE
|
|

|
Model
132-070 consists of Basic Valve(BALEM 130),
Two Pressure Reducing Pilot Valve(Model
562) and 3-Way Solenoid. It has one pilot
set at a higher pressure setting for times
of high water demand; a second pilot set
at a lower pressure setting for low demand
for getting the direct effect as saving
water in a high flowing water rate.
The
valve needs an electric power source. It
also needs a control system to change the
desired time according to flow change of
Solenoid valve.
|
|
|
|
|
BALEM
133-010
|
PRESSURE
RELIEF & PRESSURE SUSTAINING VALVE
|
|

|
Model
133-010 consists of Basic Valve(BALEM 130)
and Relief Pilot valve(Model 573). It is
installed at bypass of the pipe line in
order to prevent damage on pipe by discharging
high pressured water to atmosphere once
the pipe pressure increased higher than
the pre-set pressure, and strengthen the
maintenance of constant pressure at the
inlet pressure within the pre-set pressure.
To protect equipment in the pipeline, when
pressure raises rapidly, valve will open
fast and when valve closes, closes slow
to protect surges and can adjust the speed
of the opening and closing.
WATCH
A VIDEO DEMONSTRATION
|
|
|
|
|
BALEM
133-020
|
PRESSURE
RELIEF/SUSTAINING & CHECK VALVE
|
|

|
Model
133-020 consists of Basic Valve(BALEM 130)
and Pressure Relief Valve(Model 573). It is
installed at bypass of the pipe line in order
to prevent damage on pipe by discharging high
pressured water to atmosphere once the pipe
pressure increased higher than the pre-set
pressure, and strengthen the maintenance of
constant pressure at the inlet pressure within
the pre-set pressure. Also, once downstream
pressure is higher than inlet pressure close
the basic valve in order to prevent the backflow
caused by back pressure. To protect eqiupment
in the pipeline, when pressure raises rapidly,
valve will open fast and when valve closes,
closes slow to protect surges and can adjust
the speed of the opening and closing. |
|
|
|
|
BALEM
133-030
|
PRESSURE
RELIEF/SUSTAINING & SOLENOID ON-OFF
VALVE
|
|

|
Model
133-030 consists of Basic Valve(BALEM 130)
and Pressure ReliefPilot Valve(Model 573),
and Solenoid Valve. It is installed at Bypass
line prevents pipe-system damage caused by
pressure increased higher than preset pressure,
discharge high pressured liquid to atmosphere
relief preventing feature for pressure increase
in pipeline and maintains constant inlet pressure
within a range. It is a relief and maintain
pressure and solenoid control valve that can
control basic valve closing and opening remotely
by controling solenoid pilot valve electrically.
This valve can be provided two different types
either standard basic valve type which normally
closed(basic valve opens as solenoid operates)
and valve made to order which normally opened(basic
valve closes as solenoid operates). Optional
control features are available such as timer,
relay, probe, etc for remote control by electrical
signal depends on users' site condition. |
|
|
|
|
BALEM
133-040
|
PRESSURE
RELIEF & SURGE ANTICIPATOR VALVE
|
|

|
Model
133-040 consists of Basic Valve (BALEM 130),
Pressure Relief Pilot Valve (Model 573)
and Pressure Reducing Pilot Valve (Model
562) The valve is installed at bypass line
for protecting pumps and pipe-line systems
from dangerous surges caused by rapid changes
of flow velocity within the pipeline. The
valve anticipates the down pressure caused
by the abrupt stopping of the pump and opening,
closing of valve, immediately opens to prevent
high pressure in pipeline and has set to
minimize high pressure, relives excessive
setting pressure.
|
|
|
|
|
BALEM
137-010
|
CHECK
VALVE
|
|

|
Model
137-010 consists of Basic Valve(BALEM 130)
and Two Flow Control valve. The valve is
installed at outline of pump to prevent
back flow caused by back pressure.
The
valve opens slowly to prevent sudden opening
surges, when a pressure reversal occurs
the higher downstream pressure is applied
to the cover chamber through the control
tube lines, and the valve closes drip tight.
|
|
|
|
|
BALEM
138-010
|
SOLENOID
CONTROL VALVE
|
|

|
Model
138-010 consists of Basic Valve (BALEM 130)
and Solenoid on-off Pilot Valve. It opens
or closes upon receiving an electrical signal
to the solenoid pilot control. This valve,
as a solenoid pilot valve, can be provided
two different types.
The standard basic valve which normally
closed(basic valve opens as solenoid operates),
and valve made to order which normally opened(Basic
valve closes as solenoid operates). Optional
control features are available, such as
timer, relay, probe, etc for remote control
by electrical signal depends on users' site
conditions
|
|
|
|
|
BALEM
138-020
|
SOLENOID
CONTROL & EMERGENCY CUT-OFF VALVE
|
|

|
Model
138-020 consists of Basic Valve(BALEM 130),
Solenoid On-Off Pilot Valve and the limit
switch. The valve can control solenoid pilot
valve according to an electrical signal
so valve opens and closes rapidly.
The
valve has dual Normal Open type solenoid
valves and dual Normal Close type solenoid.
When power failure or leakage occurs the
valve senses the flow and closes promptly
for preventing the damage in pump filed
or automatic control system.
|
|
|
|
|
BALEM
139-010
|
BOOSTER
PUMP CONTROL VALVE
|
|

|
Model
139-010 is designed for installation on
the discharge of booster pumps to eliminate
pipeline surges caused by the starting and
stopping of the pump. If power failure occurs,
the valve immediately closes preventing
return flow regardless of control mode.
|
|
|
|
|
BALEM
139-020
|
DEEP
WELL - PUMP CONTROL VALVE
|
|

|
Model
139-020 consists of Basic Valve(BALEM 130),
Solenoid Pilot Valve and Limit Switch. It
is installed at outline of Deep Well Pump
to protect pipelines from surges caused
by the starting and stopping of pumps.
With
the pump off, the valve is wide open. When
the pump is started, the valve begins to
close slowly, discharging air and the initial
rush of sand and water from the pump column
to atmosphere. As the valve closes the pump
output is gradually diverted into the main
line preventing the starting surge caused
by the stopping of the valve.
|
|
|
|
|
BALEM
130-CL-01
|
FLOW
ADJUSTING ASSEMBLY
|
|
![]()
| | | | |