| | www.pvl.co.uk | | Newsletter 48. |
| | | Flow and Level Sensors from PVL, including ATEX options (and don’t forget limit switches and pressure-converters!) For any more information or details about the products below please do not hesitate to contact us on 01892 664499, alternatively you can email us on info@pvl.co.uk or visit www.pvl.co.uk Best Regards PVL | |  |
| |
| | Martens Flow Rate Sensor FS 242 | | Videos |
| | | | | |
| |  | Flow rate Sensor FS 242 The FS242 pelton-wheel flow-rate sensor provides either a pulsed (NPN/PNP) or an analogue (4-20mA loop) output. - Measuring range from 0.5 – 6 m/sec
- Accuracy 2.5% of the measured value + 0.5% from end value
- Repeatability 0.5%
- Process pressure 0 - 10bar
- Medium temperature 0 - 60°C
- uPVC paddle with ceramic bearing
- Protection IP65
more… | |
| | Martens Flow Sensor FS 222 | | Social Media |
| | | | | To find out latest PVL updates, new press releases or general information please follow us on twitter and subscribe to our blog by clicking here! |
| |  | Flow Sensor FS 222 This turbine flow sensor has been specially designed for measuring the flow of liquids of low viscosity. - High chemical resistance – all PVDF construction
- Six measuring ranges from 0.1 - 120 l/min
- ¼”; ½”; ¾”; or 1 ¼” BSP
- Accuracy 1.5%
- Supply voltage 8-24V DC
- Pressure range max. 10bar
- Integrated filter option
more… | |
| | Martens ATEX Hydrostatic Level Sensor | |
| | | | |
| |  | ATEX Hydrostatic Level Sensor IL 10 Designed for level measurement in hazardous areas, the IL10 level sensor provides an analogue 4-20mA loop output for 2-wire (twisted pair) connection. - ATEX II 1G EEx ia IIC T6
- Applicable in following Ex areas:
gases and mist: Zone 0, Zone1 und Zone 2 - dust area: Zone 20, Zone 21 und Zone 22
- Measuring ranges from 0 - 100mbar up to 0 - 25bar relative
- Accuracy 0.5%
- Flush diaphragm
- Operating temperature -10 - 60°C
- Supply voltage 10 - 30V DC
- Stainless steel 1.4571 housing
- Protection IP68 (max. 300m depth of immersion)
- International approvals ATEX, FM (USA) and CSA (Canada)
more… | | |
| | Martens LK 10 Level Sensor | | |
| | | | | |
| |  | Level sensor LK 10 Designed specifically for chemical and sewage applications. - Measuring range from 0- 0.16bar up to 0 - 16bar relative
- Accuracy 0.5%
- Flush diaphragm with Parylene coating
- Max. Medium temperature 0 - 50°C
- Supply voltage 12 - 36V DC
- PUR or FEP cable *
- Sensor sheath PVC, seal Viton® **
- Protection IP68
* PUR-cable -> Diesel oil, fuel oil, rape oil, carbonic acid FEP-cable -> Chem. aggressive liquids, acid, caustic solution heavy loaded wastewater, sewage technology (ferric-III-chloride) | | |
| | Martens LS10 Level Sensor | |
| | | | |
| |  | Level sensor LS 10 level sensor provides hydrostatic level measurement in soft-drink processing, brewing and drinking water processing. - Measuring range from 0-100mbar up to 0-10bar relative
- Output 4-20mA, loop powered
- Accuracy 0.5% (0.25-10bar), 025% (0.1- 0.16bar)
- Flush diaphragm
- Operating temperature 10-60°C
- Supply voltage 10-30V DC
- PUR-cable*; with cord fastener up to 1kN
- Stainless steel 1.4571 housing
- Protection IP68 (max. 100m depth of immersion)
more… | |
| | Martens Vibration Limit-Switch VS51 | |
| | | | |
| |  | The Martens vibration limit switch VS51 is certified as a maximum level switch to the standards of the German WHG (Water Act). - Switching indication with LEDs
- Electronic output or switching output
- Max. process pressure - 1- 64bar
- Max. process temperature – 40-100°C
- Viscosity-dynamic 0.1 - 10000mPa s
- Density 0.7 - 2.5 g/cm³ (0.025 - 0.09 lbs/in³)
- 4-pole angle entry plug acc. to DIN EN 175301-803/A
- Material case and vibration fork: stainless steel 1.4435
- Process thread G3/4A or G1A
more… | |
| | Martens Pressure Converter LPC 60 | |
| | | | |
| |  | Pressure-Converter LPC 60 The Martens LPC-60 pressure converter is designed for dry, non-aggressive process gases at pressures between 0.1 and 25 mbar and provides an analogue 4-20mA 2-wire output. - Uni- and bi-directional devices
- Zero point and span adjustable, ±5%
- Accuracy 0.8% (optional 0.4%)
- Process connection 1/4" pressure tubes (4.7mm)
- Loop voltage 12 - 36V DC
- Operating temperature -18 - 70°C (comp range 0 - 55°C)
- Wall- and TS35 DIN-rail mounting
- Note: the device is factory calibrated for vertical mounting
more… | |
| For anymore information needed on any of the above products please visit www.pvl.co.uk or call us on 01892 664499 |
Send to a colleague? If you like the information we provide about our switches, sensors and meters, please pass this email to someone else who might be interested, or ask them to ‘Register Online’ to receive their own copy. To see our policy on how we protect customer contact details, please read our Privacy Policy. If you no longer wish to receive this newsletter then please Click here and you will be unsubscribed instantly |
PVL Ltd, Unit 9 Lexden Lodge Industrial Estate, Jarvis Brook, Crowborough, East Sussex, TN6 2NQ, UK T: 01892 664499 F: 01892 663690 E: info@pvl.co.uk W: www.pvl.co.uk Registered Company No. 2792872 E&0E © 2009 PVL Ltd |