  • Intrinsically safe input ATEX II (1) G [Ex ia] IIC ATEX II (1) D [Ex iaD]
  • Basic accuracy 0.2 % (0.1 % factory calibration for one range available)
  • 2- or 3-wire connection
  • Current burden max. 1000 Ω
  • Start- and End-value adjustable
  • Full 3-port isolation
  • Supply voltage 10 ... 30 V AC/DC or 85 ... 253 V AC/110 ... 125 V DC
  • 22.5 mm case for DIN rail mounting
Download a datasheet for the MU500Ex Temp Transmitter here..
Download a datasheet for the

Brand:  Martens



Get a Quote Now or Discuss Your Requirements.


Call +44 (0)1892 664499



  • Intrinsically safe input ATEX II (1) G [Ex ia] IIC ATEX II (1) D [Ex iaD]
  • Pt100: 13 measuring range switch selectable Pt1000: 16 measuring range switch selectable
  • Basic accuracy 0.2 % (0.1 % factory calibration for one range available)
  • 2- or 3-wire connection
  • Linearize outputs 0/4 ... 20mA and 0/2 ... 10V DC
  • Current burden max. 1000 Ω
  • Start- and End-value adjustable
  • Full 3-port isolation
  • Supply voltage 10 ... 30 V AC/DC or 85 ... 253 V AC/110 ... 125 V DC
  • 22.5 mm case for DIN rail mounting