| Balem 132-030 Pressure Reducing & Sustaining Valve - Maintains constant downstream pressure
- Accurate Response to Slight Pressure Changes
- Completely automatic operation without Electric Power Source
- Drip Tight, Safe Hydraulic Control
- WATCH A VIDEO DEMONSTRATION
|
|
| Balem 132-040 Pressure Reducing/Sustaining & Check Valve - Maintains inlet pressure change
- and/or downstream pressure flow rate to a predetermined minimum pressure.
- Completely automatic operation without Electric Power Source
- Prevents Backflow Occurred by Back Pressur
|
|
| Balem 132-050 Pressure Reducing & Solenoid Shut-Off Valve - Automatically reduces higher inlet pressure to a steady lower downstream pressure
- Accurate Pressure Control
- Quick Acting Solenoid Shutoff
|
|
| Balem 132-060 Pressure Controller & 2 State Pressure Control Valve Model 132-060 consists of Basic Valve(BALEM 130), Two Pressure Reducing Pilot Valve(Model 562) and Valve Control Device(Model VCD-01). It has one pilot set at a higher pressure setting for times of high water demand; a second pilot set at a lower pressure setting for low demand. This valve is suitable for many pressure control applications for high two-pressure control of a distribution zone. Controller can be used without electric power because of a built-in battery and also program is easily set by remote control.
|
|
| Balem 132-070 2-Stage Pressure Reducing & Solenoid Control Valve Model 132-070 consists of Basic Valve(BALEM 130), Two Pressure Reducing Pilot Valve(Model 562) and 3-Way Solenoid. It has one pilot set at a higher pressure setting for times of high water demand; a second pilot set at a lower pressure setting for low demand for getting the direct effect as saving water in a high flowing water rate. The valve needs an electric power source. It also needs a control system to change the desired time according to flow change of Solenoid valve. |
|
| Balem 133-010 Pressure Relief & Pressure Sustaining Valve Model 133-010 consists of Basic Valve(BALEM 130) and Relief Pilot valve(Model 573). It is installed at bypass of the pipe line in order to prevent damage on pipe by discharging high pressured water to atmosphere once the pipe pressure increased higher than the pre-set pressure, and strengthen the maintenance of constant pressure at the inlet pressure within the pre-set pressure. WATCH A VIDEO DEMONSTRATION |
|
| Balem 133-020 ressure relief/Sustaining & Check Valve Model 133-020 consists of Basic Valve (BALEM 130) and Pressure Relief Valve(Model 573). It is installed at bypass of the pipe line in order to prevent damage on pipe by discharging high pressured water to atmosphere once the pipe pressure increased higher than the pre-set pressure, and strengthen the maintenance of constant pressure at the inlet pressure within the pre-set pressure. Also, once downstream pressure is higher than inlet pressure close the basic valve in order to prevent the backflow caused by back pressure.
|
|
| Balem 133-030 Pressure Relief/Sustaining & Solenoid ON-OFF Valve Model 133-030 consists of Basic Valve and Pressure ReliefPilot Valve(Model 573), and Solenoid Valve. It is installed at Bypass line prevents pipe-system damage caused by pressure increased higher than preset pressure, discharge high pressured liquid to atmosphere relief preventing feature for pressure increase in pipeline and maintains constant inlet pressure within a range.
|
|
| Balem 133-040 Pressure Relief & Surge Anticipator Valve Model 133-040 consists of Basic Valve (BALEM 130), Pressure Relief Pilot Valve (Model 573) and Pressure Reducing Pilot Valve (Model 562) The valve is installed at bypass line for protecting pumps and pipe-line systems from dangerous surges caused by rapid changes of flow velocity within the pipeline.
|
|
| Balem 137-010 Check Valve
Model 137-010 consists of Basic Valve(BALEM 130) and Two Flow Control valve. The valve is installed at outline of pump to prevent back flow caused by back pressure. The valve opens slowly to prevent sudden opening surges, when a pressure reversal occurs the higher downstream pressure is applied to the cover chamber through the control tube lines, and the valve closes drip tight. |
|
| Balem138-010 Solenoid Control Valve Model 138-010 consists of Basic Valve (BALEM 130) and Solenoid on-off Pilot Valve. It opens or closes upon receiving an electrical signal to the solenoid pilot control. This valve, as a solenoid pilot valve, can be provided two different types.The standard basic valve which normally closed(basic valve opens as solenoid operates), and valve made to order which normally opened (Basic valve closes as solenoid operates |
|
| Balem 138-020 Solenoid Control & Emergency Cut-Off Valve Model 138-020 consists of Basic Valve(BALEM 130), Solenoid On-Off Pilot Valve and the limit switch. The valve can control solenoid pilot valve according to an electrical signal so valve opens and closes rapidly.The valve has dual Normal Open type solenoid valves and dual Normal Close type solenoid. When power failure or leakage occurs the valve senses the flow and closes promptly for preventing the damage in pump filed or automatic control system. |
|
| Balem 139-010 Booster Pump Control Valve Model 139-010 is designed for installation on the discharge of booster pumps to eliminate pipeline surges caused by the starting and stopping of the pump. If power failure occurs, the valve immediately closes preventing return flow regardless of control mode. - Built-in Check action
- Valve uses line pressure for operation
- Opening and closing rates can be adjusted seperately
- WATCH A VIDEO DEMONSTRATION
|
|
| Balem 139-020 Deep Well - Pump Control Valve Model 139-020 consists of Basic Valve(BALEM 130), Solenoid Pilot Valve and Limit Switch. It is installed at outline of Deep Well Pump to protect pipelines from surges caused by the starting and stopping of pumps. With the pump off, the valve is wide open. When the pump is started, the valve begins to close slowly, discharging air and the initial rush of sand and water from the pump column to atmosphere.
|
|
| Balem 130-CL-01 Flow Adjusting Assembly Model CL-01 is installed at upper cover of the basic valve (BALEM 130) and regulate flow through the vavle from full flow to shut-off. These adjustable assemblies control flow by limiting the amount of the valve opening. Easy to adjust and read the condition of opening and closing and indication mark is shown by percentage. -
Easy Adjustments - Indication mark shows percentage
- Easy to read
|
|
| Balem 130-EP-01 Pump Control Panel Model EP-01 provides control of the pump and pump control valve preventing surges in the system when the pump starts or stops. It consists of an electric control panel employing a programmable logic controller. Externally mounted indicator lights provide local visual indication of normal operation and alarm conditions which is simplifying field wiring installation. - Indicator Lights Monitor System Status
- Suitable for all Booster Pump and Deep Well Applications
|